Infant Resuscitator (250 ml) Model RSB 1001
Infant Resuscitator (250 ml) Model RSB 1001
Infant Resuscitator (250 ml) Model RSB 1001
Infant Resuscitator (250 ml) Model RSB 1001
Follow Us : Follow On Facebook Follow On Twitter Follow On Youtube
The following is a Sponsored Resource. The sponsor of this content has editorial control
 
ZEAL MEDICAL EQUIPMENTS
Zeal Medical EquipmentsZeal Medical EquipmentsZeal Medical Equipments
Infant Resuscitator ( 250 ml )  MODEL: RSB 1001
Infant Resuscitator (250 ml) Model RSB 1001
Infant Resuscitator Model RSB 1001
Rugged; 100% Autoclavable; Reusable
Infant Resuscitator Model RSB 1001
250 ml silicone below
Infant Resuscitator Model RSB 1001
Non rebreathing valve with 40 cm of H2O pressure release
Infant Resuscitator Model RSB 1001
Mask size : No. 00
Infant Resuscitator Model RSB 1001
360° swiveling patient connector
Infant Resuscitator Model RSB 1001
Corrugated PVC Oxygen Reservoir
Infant Resuscitator Model RSB 1001
1.5 mtr. PVC oxygen tubing
 SKIN / AIR MANUAL ( Micro Computer Temperature Controllers )
  • 1` bright skin temp. display  1" bright skin temp. display
  • 1` bright air temp. display  1" bright air temp. display
  • % of heater output display  % of heater output display
  • Control mode display on LCD Control mode display on LCD
  • Set temp. display on LCD Set temp. display on LCD
  •  Manual Mode

  • Time programmable  Time programmable
  • Heater output settable  Heater output settable
  • Over temp. cutoff  Over temp. cutoff.


  •  Timer / APGAR Timer Baby attending alarm Auto audio alarm mute Mute  time programmable Safety Alarms Messages on LCD

     Skin Mode

  • Skin high 0.5° C Skin high 0.5° C
  • Skin low 0.5° C Skin low 0.5° C
  • Skin over range (>38° C) Skin over range (>38° C)
  • Skin under range (<34° C) Skin under range (<34° C)
  • Skin probe failure Skin probe failure
  •  Air Mode

  • Air high 1.5° C  Air high 1.5° C
  • Air low 3.0° C  Air low 3.0° C
  • Air over range  Air over range
  • Air probe failure  Air probe failure


  •  Safety high temp. cutoff at

  • Skin temp. >38° C  Skin temp. >38° C
  • Air temp. >39° C  Air temp. >39° C


  •  Heater & Power failure alarm




    For Further Details Contact:
    Zeal Medical Pvt. Ltd.
    4/19 -A, Piramal Indl. Est., S. V. Road, Goregaon (W),
    Mumbai 400062. India
    Tel:.91 22 2876 02 74
    TeleFax 91 22 2876 19 05
    Email:. zealmedi@bom3.vsnl.net.in
    Website:. http://www.zealmedical.com

    Pediatric Oncall does not endorse any specific product, service, or treatment.
    levioza
    Levioza
    Login
    levioza
    User Name :
    Password :
     
     
     
     
     
    Educational Section
     
    Disclaimer:
    The information given by www.pediatriconcall.com is provided by medical and paramedical & Health providers voluntarily for display & is meant only for informational purpose. The site does not guarantee the accuracy or authenticity of the information. Use of any information is solely at the user's own risk. The appearance of advertisement or product information in the various section in the website does not constitute an endorsement or approval by Pediatric Oncall of the quality or value of the said product or of claims made by its manufacturer.
     
    copyright ©2011 website design & development by Levioza
    Follow Us
    Follow us on :
    Folllow Us