MULTI-PARAMETER PATIENT MONITOR   MODEL : MPPM1001
DISPLAY

Type : 640 X 480 pixel color TFT
Screen Size : 10.4 inch diagonal


DISPLAYED PARAMETERS

Time : Battery-backed quartz crystal clock
Alarms: Hi & lo limits selectable on patient para.
ECG     : ECG Waveform Scale, displayed lead
Heart Rate : Derived from ECG
NIBP : Pressure (systolic, mean and diastolic)
Pulse Ox.: Pulse Rate, Pulse waveform, & % sat   
RR Apnea  : Respiration rate derived from ECG.
Trends : HR, RR, NIBP, Temp.& SpO2
Temperatures  : One channel (2nd channel optional)
Trace Freeze  : Traces A or B


ECG

Protected against defib. & electro surgery potentials

Standard Lead   I, II, III, AVL, AVR, AVF, V1, V2, V3, V4, 5,V6
Display  5, 7, 10,15, 20, 25mm/mV
Gain Scales    
Sweep Speed 12mm/s, 25mm/s, 50mm/s
Input Resis. > 5M Ohm
Freq. Response 0.05Hz-100Hz (3dB)
C M R R  >80dB
Electrode Offset Maximum ±0.3V
Potential
Baseline
Recovery
<5s after 5KV defibrillation
Heart Rate range 15 to 300bpm
Resolution 1bpm
Accuracy     <100bpm ±1% =100bpm ±2%
Alarm Heart rate hi & lo limits alarm delay<12s
Lead Off condition Detected and displayed


Spo2

Display range   0 to 100%
Accuracy   80-100%:±2digits; 7   0-69% Unspecified 0-80%:±3digits;
Alarm delay Spo2 hi & lo limits alarm delay<7s
Resolution 1%   
Display Update  <5s


PULSE RATE

Measurement Range 20 to 250bpm
Resolution 1bpm • Accuracy : ±1bpm
Alarm delay Pulse rate hi & lo limits alarm delay<7s


RR

Technique Trans-thoracic impedance (RA-LL)
Range   0-100 rpm     •    Resolution         : 1 rpm
Accuracy     ±2 rpm (0-60rpm)
Alarm delay    Resp. rate hi & lo limits alarm delay<7s


TEMP

Technique Resistance 
Channels One channel (2nd channel optional)
Scales F. Or C.
Range 0-50. • Resolution : 0.1. • Accuracy ±0.1.
Alarm delay Body temperature hi & lo limits alarm delay<7s


NIBP

Technique   Oscillometric method (with inflatable cuff)
Patient Types  Adult, Pediatric and Neonate
Cuff Inflation Time 3-15 seconds depending on cuff size.
Cuff Inflation Pressure Initially 180mmHg for Adult/Pediatric (100 or 70     mmHg for Neonate). Subsequent inflation       pressures determined by last measured systolic    pressure.
Measurement Modes Manual Immediate upon operator command AUTO Determinations automatically made with  selectable intervals. STAT    Determinations continues in 5 minutes
Measurement Range
Adult :
Systolic   :        30-255mmHg

Diastolic : 15-220mmHg

Mean Arterial 20-235mmHg
Infant:  
Systolic   :        25-220mmHg

Diastolic : 10-150mmHg

Mean Arterial 15-160mmHg
Pressure Resolution 1mmHg
Accuracy 
Cuff Pressure Range: 0to 275mmHg
Pressure Span Accuracy: ±3mmHg
Mean difference: ±5mmHg
Standard deviation 8mmHg
Determination Time

Typically 25seconds. Varies with patient's PR,

  pulse pressure and amount of artifact present.

Over pressure Valve

Automatically releases cuff pressure if inflation

Pressure exceeds 280mmHg (Adult) /150mmHg   (Neonate).
Overtime Protection  Stop determinates if the measurement time
exceeds 120s (Adult)/90s. (Neonate).
Alarm delay Pressure hi & lo limits alarm delay<7s


POWER REQUIREMENTS

Power Supply 100~240VAC,50/60Hz 1.6A max
Internal Battery 12V 7AH; Type- sealed lead-acid
Operating Time (fully charged battery) 2 hours typical at 25.,no printing, one NIBP measurement per 15 min.


ENVIROMENT

Operating Temp: 5. to 45.
Relative Humidity: 0 to 80%, non-condensing
Height of sea level: -500m ~ 4600m


The transport and storage environment should comply with the following conditions:

Storage Temperature: -20. to 70.
Relative Humidity: 0 to 93%, non-condensing
Height of sea level: -500m ~ 13100m


OPTIONAL ACCESSORIES

Thermal Printer

IBP modules

SPO2 sensors

NIBP cuffes

2nd Temperature Channel / Probe,

  Critical Care  
  Search  
Hospitals
Pediatrician
Special Schools
Medical Colleges
Pediatric Conferences
Jobs & Vacancies
Journals
 
Parent Corner l Kids Corner l Terms & Condition l Advertising l Feedback l Awards
About Us
l Link to Us l Site Map l Shopping Mall  
Partner Sites
 HIV in Children  Infection in Children  Pedcall  Medical ADRIS  Vaccine Reminder  Pediatric Oncall Journal

Copyright© 2000-2007 All rights reserved with Levioza

Disclaimer:The information given by www.pediatriconcall.com is provided by medical and paramedical & Health providers voluntarily for display & is meant only for informational purpose. The site does not guarantee the accuracy or authenticity of the information. Use of any information is solely at the user's own risk. The appearance of advertisement or product information in the various section in the website does not constitue an endorsement or approval by Pediatric Oncall of the quality or value of the said product or of claims made by its manufacturer.

 
Sitemap For Doctor | Sitemap For Parent | Sitemap For Kids Site designed and maintained by Levioza